MAYO CLINIC

MALE INCONTINENCE WRAP TO PREVENT HAPI FROM USE OF FOLEY CATHETER & INCONTINENCE

Mary M. Famorca, MAN, RN, WCC, COCN, CCCN, Charles Peworski, BSN, MSN, RN Mayo Clinic AZ, Phoenix Arizona

01

Background

Patients with incontinence have an increased risk of perineal dermatitis or incontinence associated dermatitis (IAD), pressure injury (PI), hip fracture and falls if no containment measures or strategies are employed.

​

Indwelling Foley Catheter (FC) are designed and utilized in an effort to contain urine and to reduce the patient's comorbid conditions. However, continued FC use has been proven to cause urethral erosion, creating injury in the form of a mucosal pressure injury (MPrI).

Condom catheters are external collection devices utilized in the inpatient setting to contain urine when an indwelling catheter is not appropriate. Condom catheter use also has documented cases of skin irritation and MPrI development.

Although skin irritation and MPrI rarely occur in the use of these urine containment products, their use increases the risk of bleeding at the edges of the urethra and development of a urinary tract infection. Depending on the severity of injury, surgical intervention and reconstruction may be required.

In addition, penile erosion in male patients can cause psychological pain due to disfigurement.

​

Nurses from Wound Ostomy Service Team and Wound Ostomy Resource Team gathered together to address the following issues:

  • Male patients developing MPrI with the use of Foley catheter

  • Male patients developing HAPI due to urinary incontinence

​​

Significance:

January to early May the Hospital Acquired Pressure Injury (HAPI) occurrences demonstrated 3 MPrI to the penis due to FC use & 9 HAPI due to incontinence. Urinary incontinence is one indication for FC use. The hospital's IAD incidence rate in 2017 was 36-38% with HAPI rate of 9 to 12% in the same year.

02

METHOD

  • 3 units from the hospital volunteered to trial a different absorbent external collection device (Male Incontinence Wrap)

  • Nurses in the volunteer units were given the freedom to use the Male Incontinence Wrap for male incontinent patients or current practice. Nurses who used the Male Incontinence Wrap completed a survey form

  • 39 patients were observed during the trial period

Gemini_Generated_Image_b2tieub2tieub2ti.jpg

03

PICO

​

  • Problem: MPrI, IAD, and Catheter Associated Urinary Tract Infection (CAUTI) occurrence in male patients with urinary incontinence​​​

  • Intervention: Use of Male Incontinence Wrap as an alternative for Foley catheter, condom catheter, or adult brief use​​​

  • Comparison: Current male incontinence care​​​

  • Outcome: Reduce incidence of HAPI from IAD, decrease MPrI and CAUTI from FC use. Decrease nursing time in changing the patient's brief

04

INCLUSION CRITERIA FOR TRIAL

  • Male incontinent patients

  • Male patient who does not qualify for FC but needs urinary containment device

  • Male patients who need adult briefs for urinary containment

EXCLUSION CRITERIA FOR TRIAL

  • Patients who are continent

  • Patients who have a projectile urinary stream

05

NURSES EVALUATION OF MALE INCONTINENCE WRAP

Screenshot 2026-11-28 221909.png
Gemini_Generated_Image_s7gft5s7gft5s7gf.jpg

05

Usage & Cost Comparison

Screenshot 2026-11-28 222043.png

06

CAUTI Incidence

Gemini_Generated_Image_73t44i73t44i73t4.jpg

07

RESULT

Gemini_Generated_Image_ypdcqpypdcqpypdc.jpg
Screenshot 2026-11-28 222105.png

08

DISCUSSION

  • Out of the 39 patients observed, 30 of the patients had Male Incontinence Wraps utilized by their nurses while 9 opted to use adult briefs alone.

  • 0% of the patients with Male Incontinence Wraps developed any HAPI or IAD.

  • 100% of the patients without the Male Incontinence Wrap developed HAPI from incontinence.

  • Nurses that used the Male Incontinence Wraps for their patients strongly agreed that it assisted in managing their patient's urinary incontinence and help preserve their patient's skin integrity.

  • Nurses reported that nursing time utilized to change a Male Incontinence Wrap is less than using adult brief or managing a Foley catheter.

09

CONCLUSIONS

  • Incidence of HAPI from IAD during trial decreased on units that volunteered to be part of the trial.

  • Use of Foley catheter did not reduce during trial.

  • Incidence of CAUTI was low during trial.

  • Nurses felt that time needed in changing a patient's Male Incontinence Wrap is less than when patient is using a brief.

  • Male Incontinence Wraps are another resource that nurses can utilize for their male incontinent patient to preserve patient's skin and are a viable alternative to the use of condom catheter and adult brief.

REFERENCES

  1. Gray, M., Kent, D., Ermer-Seltun, J., McNichol, L (2018). Assessment, Selection, Use & Evaluation of Body-Worn Absorbent Products for Adults with Incontinence. A WOCN Society Consensus Conference. Journal Wound Ostomy Continence Nursing, Lippincott Williams & Wilkins.

  2. . Expert Clinical Panel Deliberations External Collection Devices As An Alternative To The Indwelling Urinary Catheter: Evidence Based Review (2016). Journal of Wound Ostomy and Continence Nursing

  3. Newman, D., Fader, M., bliss, D. (2004). Managing Incontinence using Technology, Devices and Products:. Directions for Research. Nursing Research.